Clearified/fixed description of different protocol implementations
This commit is contained in:
@@ -6,11 +6,13 @@ using AMWD.Protocols.Modbus.Common.Contracts;
|
||||
namespace AMWD.Protocols.Modbus.Common.Protocols
|
||||
{
|
||||
/// <summary>
|
||||
/// Implementation of the Modbus RTU over TCP protocol.
|
||||
/// Implementation of the Modbus RTU over Modbus TCP protocol.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// The Modbus RTU over Modbus TCP is rarely used.
|
||||
/// It is a non-standard variant of Modbus TCP that includes the Modbus RTU CRC at the end of the message.
|
||||
/// It is a non-standard variant of Modbus TCP that includes wrapps a Modbus RTU message within a Modbus TCP message.
|
||||
/// <br/>
|
||||
/// Definition found on <see href="https://www.fernhillsoftware.com/help/drivers/modbus/modbus-protocol.html">Fernhill Software</see>.
|
||||
/// </remarks>
|
||||
public class RtuOverTcpProtocol : IModbusProtocol
|
||||
{
|
||||
@@ -475,16 +477,16 @@ namespace AMWD.Protocols.Modbus.Common.Protocols
|
||||
// Function code
|
||||
request[7] = (byte)ModbusFunctionCode.WriteSingleRegister;
|
||||
|
||||
byte[] addrBytes = register.Address.ToBigEndianBytes();
|
||||
request[8] = addrBytes[0];
|
||||
byte[] addrBytes = register.Address.ToBigEndianBytes();
|
||||
request[8] = addrBytes[0];
|
||||
request[9] = addrBytes[1];
|
||||
|
||||
request[10] = register.HighByte;
|
||||
request[10] = register.HighByte;
|
||||
request[11] = register.LowByte;
|
||||
|
||||
// CRC
|
||||
byte[] crc = RtuProtocol.CRC16(request, 6, 6);
|
||||
request[12] = crc[0];
|
||||
byte[] crc = RtuProtocol.CRC16(request, 6, 6);
|
||||
request[12] = crc[0];
|
||||
request[13] = crc[1];
|
||||
|
||||
return request;
|
||||
|
||||
@@ -59,8 +59,8 @@ Here you have the specific default implementations for the Modbus Protocol.
|
||||
|
||||
- ASCII
|
||||
- RTU
|
||||
- RTU over TCP
|
||||
- TCP
|
||||
- [RTU over TCP]
|
||||
|
||||
**NOTE:**
|
||||
The implementations over serial line (RTU and ASCII) have a minimum unit ID of one (1) and maximum unit ID of 247 referring to the specification.
|
||||
@@ -68,4 +68,9 @@ This validation is _not_ implemented here due to real world experience, that som
|
||||
|
||||
---
|
||||
|
||||
Published under MIT License (see [**tl;dr**Legal](https://www.tldrlegal.com/license/mit-license))
|
||||
Published under MIT License (see [**tl;dr**Legal])
|
||||
|
||||
|
||||
|
||||
[RTU over TCP]: https://www.fernhillsoftware.com/help/drivers/modbus/modbus-protocol.html
|
||||
[**tl;dr**Legal]: https://www.tldrlegal.com/license/mit-license
|
||||
|
||||
@@ -23,14 +23,14 @@ float voltage = registers.GetSingle();
|
||||
Console.WriteLine($"The voltage of device #{unitId} between L1 and N is: {voltage:N2}V");
|
||||
```
|
||||
|
||||
If you want to use the `RTU over TCP` protocol instead, you can do this on initialization:
|
||||
If you have a device speaking `RTU` connected over `TCP`, you can use it as followed:
|
||||
|
||||
```csharp
|
||||
// [...]
|
||||
|
||||
using var client = new ModbusTcpClient(host, port)
|
||||
{
|
||||
Protocol = new RtuOverTcpProtocol();
|
||||
Protocol = new RtuProtocol()
|
||||
};
|
||||
|
||||
// [...]
|
||||
|
||||