Files
AMWD.Protocols.Modbus/AMWD.Protocols.Modbus.Serial/README.md

54 lines
1.2 KiB
Markdown

# Modbus Protocol for .NET | Serial
The Modbus Serial protocol implementation.
## Example
A simple example which reads the voltage between L1 and N of a Janitza device.
```csharp
string serialPort = "COM5";
using var client = new ModbusSerialClient(serialPort);
await client.ConnectAsync(CancellationToken.None);
byte unitId = 5;
ushort startAddress = 19000;
ushort count = 2;
var registers = await client.ReadHoldingRegistersAsync(unitId, startAddress, count);
float voltage = registers.GetSingle();
Console.WriteLine($"The voltage of device #{unitId} between L1 and N is: {voltage:N2}V");
```
If you want to use the `ASCII` protocol instead, you can do this on initialization:
```csharp
// [...]
using var client = new ModbusSerialClient(serialPort)
{
Protocol = new AsciiProtocol();
};
// [...]
```
## Sources
- Protocol Specification: [v1.1b3]
- Modbus Serial line: [v1.02]
---
Published under MIT License (see [choose a license])
[v1.1b3]: https://modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf
[v1.02]: https://modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
[choose a license]: https://choosealicense.com/licenses/mit/