# Modbus Protocol for .NET | Common
|
|
|
|
This package contains all basic tools to build your own clients.
|
|
|
|
### Contracts
|
|
|
|
**IModbusConnection**
|
|
This is the interface used on the base client to communicate with the remote device.
|
|
If you want to use a custom connection type, you should implement this interface yourself.
|
|
The `IModbusConnection` is responsible to open and close the data channel in the background.
|
|
|
|
**IModbusProtocol**
|
|
If you want to speak a custom type of protocol with the clients, you can implement this interface.
|
|
|
|
**ModbusBaseClient**
|
|
This abstract base client contains all the basic methods and handlings required to communicate via Modbus Protocol.
|
|
The packages `AMWD.Protocols.Modbus.Serial` and `AMWD.Protocols.Modbus.Tcp` have specific derived implementations to match the communication types.
|
|
|
|
|
|
### Enums
|
|
|
|
Here you have all typed enumerables defined by the Modbus Protocol.
|
|
|
|
- Error code
|
|
- Function code
|
|
- Device Identification Category (Basic, Regular, Extended, Individual)
|
|
- Device Identification Object
|
|
- ModbusObjectType (only needed when using the abstract base type `ModbusObject` instead of `Coil`, etc.)
|
|
|
|
|
|
### Extensions
|
|
|
|
To convert the Modbus specific types to usable values and vice-versa, there are some extensions.
|
|
|
|
- Decimal extensions for `float` (single) and `double`
|
|
- Signed extensions for signed integer values as `sbyte`, `short` (int16), `int` (int32) and `long` (int64)
|
|
- Unsigned extensions for unsigned integer values as `byte`, `ushort` (uint16), `uint` (uint32) and `ulong` (uint64)
|
|
- Some other extensions for `string` and `bool`
|
|
|
|
|
|
### Models
|
|
|
|
The different types handled by the Modbus Protocol.
|
|
|
|
- Coil
|
|
- Discrete Input
|
|
- Holding Register
|
|
- Input Register
|
|
|
|
In addition, you'll find the `DeviceIdentification` there.
|
|
It is used for a "special" function called _Read Device Identification_ (0x2B / 43), not supported on all devices.
|
|
|
|
The `ModbusDevice` is used for the server implementations in the derived packages.
|
|
|
|
|
|
### Protocols
|
|
|
|
Here you have the specific default implementations for the Modbus Protocol.
|
|
|
|
- ASCII
|
|
- RTU
|
|
- RTU over TCP
|
|
- TCP
|
|
|
|
**NOTE:**
|
|
The implementations over serial line (RTU and ASCII) have a minimum unit ID of one (1) and maximum unit ID of 247 referring to the specification.
|
|
This validation is _not_ implemented here due to real world experience, that some manufactures don't care about it.
|
|
|
|
---
|
|
|
|
Published under MIT License (see [**tl;dr**Legal](https://www.tldrlegal.com/license/mit-license))
|